
PD-101 Full-Face Industrial Air Purifying Respirator (APR) with A1 Organic Vapor (OV) with P2 Particulate Filter Canister - Burnt Bronze / 5-Pack
Product information for PD-101 Full-Face Industrial Air Purifying Respirator (APR) with A1 Organic Vapor (OV) with P2 Particulate Filter Canister - Burnt Bronze / 5-Pack
The PD-101 Full Face Respirator is engineered for industrial applications and offers superior protection against environmental hazards. Designed for harsh conditions, it features a bayonet-style filter attachment system compatible with leading brands, ensuring easy and reliable filter changes. Built for durability, the PD-101 includes a soft, chemical-resistant natural rubber face seal, providing both comfort and long-lasting wear. The mask’s silicone material is not only easy to clean but also resists odors, making it ideal for prolonged use in tough environments. For professionals engaged in heavy-duty tasks like sawing, grinding, or hammering, the PD-101 offers a wide 78% field of vision through its impact-resistant, scratch, and stain-resistant lens. The downward-facing exhalation valve ensures cooling airflow, reducing visor fogging for enhanced visibility. Each unit is equipped with industry-standard bayonet cartridges, including a set of P-A-3 OV Cartridges. These cartridges have been tested to provide reliable filtration for organic vapors and particulates, ensuring your team's safety in the most demanding settings. Highlights: Head Harness: 5-point attachment adjustable silicon head harness Field of View: Panoramic field of view of 78%, promoting better situational awareness. Anti-Fog: Suitable for hot and cold weather environments Voice Box Diaphragm: High-quality voice box diaphragm facilitates effortless communication while wearing the mask. Impact-Resistant Lens: Full-face lens designed to withstand impact during rigorous activities. RECOMMENDED FOR: Home Improvement & DIY: Perfect for use during sanding, painting, staining, and drywall work. Small Business Applications: Ideal for light industrial tasks such as power washing, epoxy resin work, and woodworking. Airborne Particulates & Dust: Provides protection against dust, mold, and airborne particulates during various home improvement and light industrial projects. /* Base Table Styling */ .responsive-table { width: 100%; border-collapse: collapse; font-family: Arial, sans-serif; color: #000; background-color: #fff; } /* Header and Section Titles */ .responsive-table thead th { background-color: #000000; color: #fff; padding: 15px; font-size: 18px; text-align: center; font-weight: bold; border: 1px solid #ddd; } .responsive-table tbody th { background-color: #333; color: #fff; padding: 12px; font-size: 16px; font-weight: bold; border: 1px solid #ddd; text-align: left; } /* Data Cells Styling */ .responsive-table td { padding: 12px; border: 1px solid #ddd; font-size: 16px; vertical-align: middle; background-color: #F5F5F5; /* Light gray background for data cells */ color: #333; } /* Section Divider */ .responsive-table tr.section-divider th { background-color: #000000; color: #fff; padding: 10px; font-size: 16px; text-align: center; border-top: 2px solid #333; } /* Add space between sections */ .section-spacing { height: 20px; /* Adjust this value to increase or decrease the spacing */ } /* Mobile View - Keep Desktop Structure */ @media screen and (max-width: 768px) { .responsive-table th, .responsive-table td { padding: 10px; font-size: 14px; } } PD-101 Full-Face Respirator Protection Level Class 2 Head Strap 5-Point Adjustable Thread Connection Bayonet Weight 445g/15.7 oz oz Shelf Life 5 years Storage Condition Temperature -10 °C (14°F) to 35 °C (95 °F), Humidity <80% RH Inhalation Resistance 30 l/min 0.5 mbar 95 l/min 1.5 mbar 160 l/min 2.2 mbar Exhalation Resistance 160 1/min continuous flow or 50L/min sinusoidal (25 cycles/min, 2.0L/stroke) 2 mbar Inward Leakage 0.04% of inhaled air Carbon Dioxide Content of the Inhalation Air (% by vol.) 0.9% of inhaled air Effective Field of Vision 78% Overlapped Field of Vision 80% Gas Capacity A1 Test Gas: C6H12Test gas concentration: 3.5mg/LFlow: 15L/min Protection Time: 75 minutes Filter Penetration Maximum filter penetration of tested aerosol (%) Sodium Chloride test at 95 l/min with a tolerance of ±2% ≤ 0.03% Paraffin Oil test at 95 l/min with a tolerance of ±2% ≤ 1% Fit Test Compatible with TSI Fit Test Adapter 8025-16 PD-101: User Instructions PD-101 CE Certification: EN 136: 1998 Package Contents: 1 PD-101 Full Face Respirator Mask 2 P-A-3 A1 Organic Vapor (OV) with P2 Particulate Filter Canister /* Remove default anchor styling */ a { text-decoration: none; color: inherit; } body { min-width: 100%; min-height: 100vh; margin: 0; padding: 0; font-weight: 400; font-family: Arimo; } .image-text-container { text-align: center; /* Center align text and button */ display: flex; flex-direction: column; align-items: center; } .shop-now-btn-wrapper { display: flex; justify-content: center; /* Center the button horizontally */ width: 100%; margin-top: 5px; } /* Scope button styling to only affect the "Shop Now" buttons */ .shop-now-btn-wrapper button { height: 45px; width: 120px; border-radius: 25px; margin-bottom: 10px; background-color: #a70c00; color: white; border: none; cursor: pointer; } .shop-now-btn-wrapper button:hover { background-color: #383e47; color: white; } .shop-now-btn-wrapper button:active { box-shadow: 0 5px #666; transform: translateY(4px); } .all-container { margin: auto; font-family: Arimo; } .display-image { display: flex; align-items: center; justify-content: space-evenly; } .first-image { width: 370px; height: 300px; background-size: cover; } .centered-text { text-align: center; } .cert-section { background-color: #a70c00; color: white; text-align: center; } .certification-container { display: flex; justify-content: space-around; } @media only screen and (max-width: 766px) { .first-image { width: auto; height: 150px; background-size: cover; } .display-image { flex-direction: column; } } Cartridge & Filter Compatibility P-A-3 Shop Now P-3-0 Shop Now A-G-X Shop Now A-M-F Shop Now PD-101 Certifications and Tests




